Error Code TextL9
- May 23
- 1 min read
Updated: May 24
Flow sensor or flow switch detecting low flow rate on primary circuit
Cause
Water circulation issue, air in the primary circuit, zone valve/pump not energising, flow sensor reading abnormal value
Check Procedure
Check pump/zone valve operation, check connections/wiring of flow sensor and/or switch, check FTC dip switch settings
Book Your Annual Heat Pump Service Today
Don't wait until something goes wrong. At Reliable Renewables, our NVQ Level 3 qualified engineers provide comprehensive annual heat pump servicing across Nottingham, East Midlands, Yorkshire, Lincolnshire, and North England. We service all major heat pump brands including Mitsubishi Ecodan, Daikin Altherma, Vaillant aroTHERM, Samsung, and Worcester Bosch.